Pipe Dimensions
State NPS or DN, actual OD and starting wall from the applicable dimensional standard.
Mesta Inc. manufactures bends for hydrotest assemblies for controlled changes in pipeline and industrial piping direction. Each enquiry is reviewed against pipe size, wall, material, CLR, angle, test-loop interfaces, design inputs and the approved hydrotest procedure.
A bend for hydro test is a drawing-defined pipe bend intended for an engineered hydrostatic test loop, manifold or temporary test assembly. Its suitability depends on the complete test design, not on the product name alone.
The approved package should state pipe size, wall, material, CLR, angle, ends, test pressure and temperature basis, test medium, connection details, vents, drains and dimensional tolerances. Material certificates and heat traceability connect the finished bend to the approved pipe.
Mesta Inc. reviews material, geometry, interfaces, inspection and documentation before confirming the manufacturing scope. The responsible test engineer must establish the test pressure, procedure, exclusion zone and safe filling, venting, depressurising and draining arrangements. Related configurations are available on the drawing bend and flanged end bend pages.

A purchasing specification must identify the approved test package and combine bend geometry with material, interfaces, design inputs, tolerances and acceptance requirements. The applicable standard edition, pipe dimensions, material documentation and any supplementary project requirements should be identified.
| Pipe size | DN, NPS and actual outside diameter supported by the applicable dimensional standard. |
|---|---|
| Starting material | Complete pipe material specification, grade, class, edition and delivery condition. |
| Centreline radius | Exact drawing-defined CLR stated numerically in millimetres. |
| Bend angle | Project-defined angular change with permitted positive and negative tolerance. |
| Test design basis | Governing code, approved test pressure and temperature basis, test medium and responsible test procedure. |
| Wall thickness | Pipe schedule or nominal wall plus any specified minimum finished-wall requirement. |
| Tangents | Required straight length at the inlet and outlet beyond the theoretical tangent points. |
| Material records | Required certificate type, heat number traceability and supplementary test results. |
| Test connections | Weld preparations, flange details, closures and drawing-defined vent, drain or instrument interfaces. |
| Testing and documents | Dimensional, material and additional agreed inspection records required by the order. |
| Surface condition | Bare, painted or project-specified coating with preparation and inspection requirements. |
Safety note: The bend manufacturer does not set the field test pressure. The responsible engineer must approve the hydrotest procedure, component compatibility, temporary restraints, instrumentation and safe release controls.
The product name alone does not establish geometry. State the numeric CLR, angle, tangents, end planes and overall references on the controlled drawing so production and inspection teams use the same measurable requirements.
State NPS or DN, actual OD and starting wall from the applicable dimensional standard.
Place the required centreline radius directly on the drawing and define any project D-radius convention.
For angle θ in degrees, theoretical centreline arc length equals π × CLR × θ / 180.
Add the pipe radius, bend angle and any straight tangents when checking space, supports and transport.
Drawing note: Do not rely on “long radius” or the material grade alone. Use numeric dimensions and identify the drawing revision governing manufacture and inspection.
The enquiry should state the pipe material specification, grade, class, applicable edition, delivery condition, dimensions, certificate type and supplementary project requirements. Design suitability remains the purchaser's responsibility.
Verify the specification, grade, class, heat number and delivery condition against the purchase order and material certificate.
Maintain identification from incoming pipe through cutting, forming, inspection and final marking.
State positive material identification, hardness, impact, NDE and other project-specific testing requirements at enquiry stage.
Define internal and external systems, cutbacks, surface preparation, thickness and inspection separately.
Related material options include carbon steel bends, A106 Gr B bends, stainless steel bends, 3LPE bends and coated bends.
Forming feasibility depends on the combined pipe size, wall, material condition, radius and angle. Mesta Inc. reviews size, wall, material, angle, radius, tangents, quantity and acceptance criteria before confirming feasibility.
Verify the approved drawing revision, specified material, pipe dimensions and the numeric CLR and record the exact centreline radius in millimetres.
Resolve angle, tangent points, straight ends, end planes, tolerances and overall envelope.
Check the specified grade, pipe dimensions, condition and traceability before production.
Apply the approved route and controls for the pipe size, wall, material and long-radius profile.
Complete any approved heat treatment, cut to drawing dimensions, prepare the ends and perform specified surface work.
Verify the bend, compile agreed documents and prepare suitable support and protection for dispatch.
Inspection should verify material traceability, drawing-defined geometry and the formed pipe cross-section. Wall and ovality acceptance limits, measurement locations and methods must be agreed in advance.
Verify the actual CLR using the drawing-defined measurement method and approved diameter basis.
Check the included angle, tangent references, straight lengths and overall end positions.
Complete specified wall and cross-section checks at the agreed locations along the bend.
Record controlled dimensions, material traceability, end details, marking and any approved deviations.
A hydro test bend may be specified for a temporary or permanent test-loop arrangement where geometry and interfaces must match an approved test package. Project-specific uses include:
Related material and construction options include carbon steel bends, coated bends and pulled bends.
Provide the complete radius definition, pipe data and project scope so Mesta Inc. can review the requirement:
It is a hydro test bend manufactured and inspected against an approved drawing that defines geometry, material, tolerances, ends and acceptance requirements.
The responsible test engineer determines and approves the pressure and procedure under the governing code and project requirements. The bend supplier requires those design inputs but does not independently set the field test pressure.
State the required numeric centreline radius in millimetres and identify any D-radius convention used by the project.
Define welded or flanged ends, closures, flange orientation and any vent, drain, fill or instrument interfaces shown on the approved assembly drawing.
Yes, subject to technical review. The approved drawing controls the angle, radius, tangents, ends and dimensional tolerances.
Specify the complete pipe material specification, grade and delivery condition with the required material certificate, heat traceability and any supplementary testing or impact requirements.
Send the pipe size and OD, the approved drawing revision and complete material specification, numeric CLR, angle, wall, certificate requirements, tangents, ends, tolerances, testing, coating and quantity.
Send Mesta Inc. your pipe data, the approved drawing revision and complete material specification, numeric CLR, bend angle, material, wall, tangents, end details, inspection scope and quantity.
+91 22 2386 0222 / +91 22 2386 0223 +91 22 67492118 / +91 22 6636 2118 +919820007728 +919867899897 +919819546861
sales@mestainc.com nms@mestainc.com export@mestainc.net
Ground Floor, Shop No.2, Rangawala bldg., 58 Islampura Street, Near Alankar Cinema, Mumbai-400 004, India
Plot No L 85, MIDC Taloja Industrial Area, Dist.Raigad, Navi Mumbai-410 208, India
Powered by Mesta Inc | Designed and Developed by Skytech SEO Solutions